BPDQT - C140, TE SOLVENT (LIQUID)
- MSDS: BPDQT
- Manufacturer: CHEMTRONICS INC
- Product Name: C140, TE SOLVENT (LIQUID)
- National Stock Number: 6850-00N030120
Product Identification
Product ID:C140, TE SOLVENT (LIQUID)
MSDS Date:06/01/1987
FSC:6850
NIIN:00N030120
MSDS Number: BPDQT
Responsible Party
KENNESAW, GA 30144
US
Emergency Phone: 404-424-4888
Info Phone: 404-424-4888
Preparer: S.H. STEIN
Cage: 2M589
Contractor
Telephone: 770-424-4888/800-645-5244
Cage: 2M589
Ingredients
PERS. DO NOT INDUCE VOMIT AS HAZ OF ASPIR
RTECS: 9999999ZZ
PROGRESS THROUGH INTESTINAL TRACT. CALL MD. NOTE TO
RTECS: 9999999ZZ
DYSRYTHMIAS, CATECHOLAMINE DRUGS, SUCH AS
RTECS: 9999999ZZ
LIFE-THREATENING EMERGENCIES.
RTECS: 9999999ZZ
ETHYL ALCOHOL;(ETHANOL)
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 4%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
CAS: 76-13-1
RTECS: KJ4000000
Fraction By Weight: 95%
OSHA PEL 1000PPM
ACGIH TLV: 1000PPM/1250STEL9394
ETHANE, NITRO-;(NITROETHANE)
CAS: 79-24-3
RTECS: KI5600000
Fraction By Weight: 1%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
RTECS: 9999999ZZ
RADIATION MAY CAUSE THE FORMATION OF CHLORIDES,
RTECS: 9999999ZZ
SHOULD BE USED IN LOW PLACES.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:VAP IS HEAVIER THAN AIR & CAN
CAUSE SUFFOCATION BY REDUCING O*2 AVAIL FOR BRTHG. BRTHG HIGH CONC
OF VAP MAY CAUSE LIGHT-HEADEDNESS, GIDDINESS, SHORTNESS OF BREATH,
& MAY LEAD TO NARCOSIS, CARDIA C IRREGULARITIES, UNCON OR DEATH.
EYE:CNTCT MAY CAUSE IRRIT, SOLV CNTNS ETHANOL. SKIN:NOT CORROSIVE
OR(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OR IRRITANT AFTER SINGLE CNTCT.
HOWEVER, RPTD LIQ CNTCT CAN CAUSE DEFAT OF SKIN RSLTG IN IRRIT.
MATL IS POORLY ABSORBED THRU SKIN. IN SCREENING STUDIES
W/EXPERIMENTAL ANIMALS, EXPOS AT APPROX 500 PPM & ABOVE, FOLLOW BY
LGE IV EPINEPHRINE CHALLENGE, HAS PRODUCED SERIOUS CARDIAC
IRREGULARITIES. (SUPP DATA)
Medical Cond Aggravated by Exposure:PREEXISTING DISEASES OF LIVER,
RETINA, CNS, GI TRACT OR REPRODUCTIVE ORGANS.
First Aid
First Aid:INHAL:MOVE TO FRESH AIR. IF NEC, GIVE ARTF RESP/O*2. DO NOT
GIVE EPINEPHRINE OR SIMILAR DRUGS AS SUCH DRUGS MAY INDUCE
VENTRICULAR ARRYTHMIA. EYE:IMMED FLUSH W/WATER FOR AT LEAST 15
MINS. CALL MD. SKI N:FLUSH W/WATER. GET MD IF IRRIT PRESENT.
INGEST:IMMED GIVE 2 GLASSES OF WATER OR ACTIVATED CHARCOAL SLURRY
(50G ACTIVATED CHARCOAL IN 100 ML WATER). NEVER GIVE ANYTHING BY
MOUTH TO UNCON (ING 7)
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Lower Limits:NONFLAMMABLE
Upper Limits:NONFLAMMABLE
Extinguishing Media:FOAM, CO2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP . ADDITION OF EXCESS WATER WILL EXTRACT ALCOHOL &
MAY FORM A FLAMMABLE, SUPERNTANT LIQ LAYER.
Unusual Fire/Explosion Hazard:PRESSURIZED AEROSOL CONTAINERS AT ELEV
TEMPS MAY VENT, RUPTURE OR BURST & ADD TO FLYING & FALLING DEBRIS.
INTENSE HEAT MAY CAUSE DECOMP W/EMISSION (SUPP DATA)
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE POSSIBLE IGNITION
SOURCES. WIPE UP SPILL & ALLOW TO EVAPORATE. WASH HANDS WITH SOAP &
WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE NEAR SOURCES OF HEAT IN
DIRECT SUNLIGHT OR WHERE TEMPERATURES EXCEED 49C/120F. DO NOT
PUNCTURE OR DAMAGE CONTAINERS. ROTATE STOCK.
Other Precautions:DO NOT SPRAY LIQ ON HANDS. DO NOT DIRECT SPRAY TO
EYES. AVOID BRTHG VAPS & PRLNGD SKIN EXPOSURE. USE ONLY IN
WELL-VENT AREA. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICIN
OF ARC WELDING, OPEN FLA MES OR HOT SURFS. HEAT &/OR UV (ING 5)
Exposure Controls
Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.
NIOSH/MSHA APPROVED SCBA IS REQUIRED IF A LARGE SPILL OCCURS.
Ventilation:NORMAL VENT FOR STANDARD MFG PROC IS GEN ADEQ. LOC EXHST
SHOULD BE USED WHEN LGE AMTS ARE RELS. MECH VENT (ING 6)
Protective Gloves:BUTYL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH:NEUTRAL. EXPLO HAZ:OF HALOGEN ACIDS. THERMAL DECOMP PRODS MAY INCL
CHLORIDES, FLUORIDES, & PHOSGENE. EFTS OF
OVEREXP:CHLOROFLUOROCARBON (CFC) MATLS HAVE PRODUCED SENSIT OF
MYOCARDIUM TO EPINE PHRINE IN LAB ANIMALS/COULD HAVE SIMILAR EFT IN
HUMANS. ADRENOMIMETICS (I.E.,EPINEPHRINE) MAY BE
CONTRA-INDICATED(ING 4)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:112F,44C
Vapor Pres:362 @ 77F
Vapor Density:2.9 @ 77F
Spec Gravity:1.51 G/CC @ 77F
pH:SUPDAT
Evaporation Rate & Reference:0.5 (ETHER=1)
Solubility in Water:MODERATE
Appearance and Odor:CLEAR WITH FAINT SOLVENT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:SPRAYING NEAR OPEN FLAMES & HIGH
TEMPERATURES.
Hazardous Decomposition Products:CMPD CAN BE DECOMPOSED BY HIGH TEMPS
(OPEN FLAMES/GLOWING SURFS/ETC.) FORMING HYDROFLUORIC ACIDS, POSS
CARBONYL HALIDES.
Disposal
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE, AND LOCAL
REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO PERMITTED WASTE
DISPOSAL FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.